EasyManua.ls Logo

Additel 761A User Manual

Default Icon
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
I
Additel 761A Automated Pressure Calibrator
————User Manual
Please download the latest version from www.additel.com
[Version:1911V01]
Additel Corporation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Additel 761A and is the answer not in the manual?

Additel 761A Specifications

General IconGeneral
BrandAdditel
Model761A
CategoryTest Equipment
LanguageEnglish

Summary

Warnings

General safety

1. Introduction

1.1 Overview

Provides a general overview of the ADT761A Automated Pressure Calibrator.

1.2 Features

Details the key features and capabilities of the ADT761A Calibrator.

1.3 Environmental Conditions

Specifies the required environmental conditions for operating and storing the calibrator.

1.4 Power

Outlines power specifications, including working time and charging details.

1.5 Specifications

Lists technical specifications for various models of the ADT761A calibrator.

2. Installation

2.1.1 Basic structure

Details the basic physical structure and components of the calibrator.

2.1.2 Electrical and signal ports

Explains the different electrical and signal ports on the calibrator.

2.1.3 Keypad

Describes the keypad layout and its associated functions.

2.1.4 Pressure ports

Details the pressure ports available on the calibrator for connections.

2.2 Initial preparation

Covers the initial steps required before operating the calibrator.

2.2.1 Battery installation

Provides instructions for installing or removing the battery.

2.2.2 Pressure connection

Explains how to connect pressure instruments to the calibrator.

2.2.3 View the display

Guides on how to position and view the calibrator's display.

2.3 Getting started

Covers the initial steps to start using the calibrator.

2.3.1 Power on

Instructions on how to turn the calibrator on.

2.3.2 Setting the system date and time

Procedure for setting the device's date and time.

2.3.3 Generating a pressure

Steps to generate and control pressure using the calibrator.

2.3.4 Display and operation

Describes the display interface and general operation of the calibrator.

3. Display and Operation

3.1 Home screen

Details the layout and components of the calibrator's home screen.

3.1.1 Status bar

Explains the information displayed in the status bar.

3.1.2 Module and split screen display area

Describes display areas for modules and split-screen functionality.

3.1.3 Main interface keypad operation

Instructions for operating the calibrator using the keypad.

3.2 Pressure control

Guides on how to control and manage pressure generation and output.

3.2.1 Pressure output

Guides on how to output and control pressure from the calibrator.

3.2.2 Pressure measurement

Instructions for performing pressure measurements with the calibrator.

3.2.3 Pressure units

How to change pressure units for internal or external modules.

3.3 Electrical signal measurement

Covers the functions for measuring electrical signals like current and voltage.

3.3.1 Current/Voltage measurement

Procedures for measuring current and voltage signals.

3.3.2 Switch test

Details on how to perform switch tests using the calibrator.

3.3.3 HART Communication

Explains HART communication setup and operation with the calibrator.

3.3.4 PROFIBUS PA communication

Explains PROFIBUS PA communication setup and operation.

3.4 Electrical output

Describes how to configure and perform electrical output functions.

3.5 External pressure module

Information on connecting and using external pressure modules.

3.6 Typical applications

Presents common applications and usage scenarios for the calibrator.

3.6.1 Pressure gauge

Application details for calibrating pressure gauges.

3.6.2 Pressure transmitter

Application details for calibrating pressure transmitters.

3.6.3 HART transmitter

Application details for calibrating HART transmitters.

3.6.4 Pressure switch

Application details for calibrating pressure switches.

3.6.5 I/P converter

Application details for calibrating I/P converters.

4. System setup

4.1 Control settings

Configuration options for pressure control parameters.

4.2 Communication

Settings for connecting the calibrator via Ethernet, Wi-Fi, or Bluetooth.

4.2.1 Ethernet

Instructions for configuring Ethernet communication.

4.2.2 Wireless communication

Settings for connecting the calibrator to a wireless network.

4.2.3 Bluetooth

Instructions for Bluetooth connection to mobile applications.

4.3 Power management

Options for managing the calibrator's power and battery.

4.3.1 Display brightness

Adjusts the brightness of the calibrator's LCD screen.

4.3.2 Battery information

Displays the current battery status and information.

4.3.3 Energy settings

Configures energy-saving features like auto-backlight and shutdown.

4.4 System calibration

Procedures for calibrating the calibrator's internal modules and external sensors.

4.4.1 Calibration of electrical measurement

Steps for calibrating the electrical measurement functions.

4.4.2 Auto tune

Procedure for optimizing controller parameters for improved performance.

4.4.3 Calibration of the supply pressure module

Calibrates the supply pressure module's sensors.

4.4.4 Calibration of the barometric pressure module

Calibrates the internal barometric pressure sensor.

4.4.5 Pressure calibration

Calibrates the calibrator's pressure measurement and output modules.

4.5 Services

Provides access to device services like firmware upgrades and maintenance.

4.5.1 System upgrade

Instructions for upgrading the calibrator's firmware via USB or remotely.

4.5.2 Maintenance

Accesses maintenance records and system board upgrade information.

4.5.3 Factory reset

Restores user settings and clears data to factory defaults.

4.6 Personalization

Customizes device settings like date, time, language, and sound.

4.6.1 Date and time

Sets the current date and time on the calibrator.

4.6.2 Language

Allows selection of the user interface language.

4.6.3 Sound

Configures audible alerts and volume settings.

4.7 Cloud service

Enables and configures connection to cloud services for monitoring.

4.8 Data management

Options for managing and exporting saved data files.

4.9 Product information

Displays detailed information about the calibrator's hardware and software.

4.9.1 Host information

Shows model, serial number, firmware, and operation time details.

4.9.2 Control board information

Information about the control panel's software and hardware versions.

4.9.3 Electrical measurement board information

Details on the electrical measurement board's versions and parameters.

4.9.4 Electrical source board information

Information on the electrical source board's versions and parameters.

4.9.5 Wireless module information

Details about the Wi-Fi and Bluetooth module versions.

4.9.6 PROFIBUS module information

Information on the PROFIBUS module's firmware and hardware.

4.9.7 HART handheld communicator information

Details about the HART handheld communicator's DD library version.

5. Documentation

5.1 Quick test

Enters a function for performing quick tests on various devices.

5.1.1 Pressure gauge

Procedure for performing a quick test on a pressure gauge.

5.1.2 Pressure transmitter

Procedure for performing a quick test on a pressure transmitter.

5.1.3 Pressure switch

Procedure for performing a quick test on a pressure switch.

5.1.4 Pressure sensor

Procedure for performing a quick test on a pressure sensor.

5.1.5 I/P converter

Procedure for performing a quick test on an I/P converter.

5.1.6 Signal isolator

Procedure for performing a quick test on a signal isolator.

5.2 Task

Manages and executes predefined calibration tasks.

5.2.1 Analog pressure gauge

Task settings and execution for analog pressure gauges.

5.2.3 Calibrate a pressure transmitter

Task for calibrating pressure transmitters, measuring output values.

5.2.4 Pressure transducer

Task settings and execution for pressure transducers.

5.2.5 Pressure switch

Task settings and execution for pressure switches.

5.2.6 I/P converter

Task settings and execution for I/P converters.

5.2.7 Signal isolator

Task settings and execution for signal isolators.

5.2.8 Contact pressure gauge

Task settings and execution for contact pressure gauges.

5.2.9 Valve opening gauge

Task settings and execution for valve opening gauges.

5.3 Quick test (for barometric (BP) version)

Performs quick tests specifically for barometric pressure versions.

5.3.1 Digital barometer

Procedure for performing a quick test on a digital barometer.

5.3.4 Barometric altimeter

Procedure for performing a quick test on a barometric altimeter.

5.3.5 Pressure transmitter

Procedure for performing a quick test on a pressure transmitter.

5.3.6 Pressure switch

Procedure for performing a quick test on a pressure switch.

5.4 Task (for barometric (BP) version)

Manages and executes calibration tasks for barometric (BP) versions.

5.4.1 Digital barometer

Task settings and execution for digital barometers.

5.4.2 Calibration of the mercury barometer

Calibrates a mercury barometer.

5.4.3 Aneroid barometer

Calibrates an aneroid barometer.

5.4.4 Barometric altimeter

Calibrates a barometric altimeter.

5.4.5 Pressure transmitter

Task settings for pressure transmitters (BP version).

5.4.6 Pressure switch

Task settings for pressure switches (BP version).

6. Application

6.1 Unit conversion

Converts between different pressure units.

6.2 Pressure leak test

Performs pressure leak detection tests.

7. HART Communication

7.1 HART connection and search

Steps to connect and search for HART devices.

7.2 HART communicator operation

Detailed operations for the HART communicator function.

8. System maintenance

8.1 Device information view

Accesses and displays device information.

8.2 Diagnostic information

Provides information on detected abnormalities and diagnostic results.

8.3 Sealing performance procedure

Checks the sealing performance of the calibrator.

8.4 Suction filter replacement

Instructions for replacing the suction filter.

8.5 Replacement of the outlet filter and o-ring

Guides on replacing the outlet filter and o-ring.

8.6 Air filter replacement

Instructions for replacing the air filter.

Related product manuals