109
S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started
GPRS Mobile Measurements
Individual pass/fail indicators are provided for each section of the mask. On the
display, text labels corresponding to the following sections change color to
indicate a pass or fail (green indicates a pass; red indicates a fail):
Rise section of burst 1
Active (useful) section of Burst 1
Guard period between burst 1 and 2 (Note: this indicator is only available if
you are measuring two uplinks)
Active (useful) portion of Burst 2 (Note: this is only available if you are
measuring two uplinks)
Fall section
NOTE When the Multi-Measurement Count parameter is set to a number
greater than 1, it is possible for some, or all of the individual pass/fail
indicators to show a pass while the overall pass/fail indicator shows a
fail. This is because the individual pass/fail indicators relate to the last
of the multi-measurements made, whereas the overall mask pass/fail
indicator is an accumulative result from all the multi-measurements
made.
You can zoom in to individual sections of the graph by pressing the Guard Period
(
F2), Burst 1 Views (F3), or Burst 2 Views (F4) keys. In addition, you can