4. Structure of the ANET3910-EN
4.7.2 Time Tag Methods
The IRIG-IN and IRIG-OUT signals shall be connected depending on the time tag
method used as shown below.
a. Single AIM-Module no external IRIG-B source
- No connection required
b. Multiple AIM-Modules with no common synchronization requirement
- No connection required
c. Single or multiple AIM-Module(s) with external IRIG-B source
- Connect external IRIG-B source to IRIG-IN and GND of all modules
d. Multiple AIM-Modules with no external IRIG-B source internally
synchronized
- Connect the IRIG-OUT signal and the GND of the module you have
chosen as the time master to all IRIG-IN signals (including the time
master).