256
TROUBLESHOOTING
Code No. /
functions
Operational procedure / display contents
12
Indicated
engine
speed
13
Apparent
engine
speed
Monitor mode
Displays indicated engine speed (code No. 12) / apparent engine speed (code No. 13).
When indicated engine speed is 1,200 rpm (min
-1
)
Command mode
Switches between forced setting and automatic setting (cancelling forced setting) of indicated
engine speed (code No. 12) / apparent engine speed (code No. 13).
Example) Method of apparent engine speed setting
Select command (Initial display)
During automatic operation During forced setting (2,200 2,050 rpm (min
-1
))
Press [SET] switch
Press [SET] switch
During command setting
Automatic setting Forced setting
Switch by pressing [UP] + [DOWN] switches simultaneously for 1 second
Change data with [UP] or
[DOWN] switch
(changes by 50 rpm (min
-1
))
Press [SET] switch
Press [SET] switch
Return to select command (setting is completed)
Apparent engine speed setting Completed
Automatic setting is completed. Forced setting is completed.
Forced setting is automatically cancelled in 10 minutes.
This function is not available when the engine is not running.
Only one of the engine speeds (indicated, apparent, total apparent) may be forced at one
time.