257
TROUBLESHOOTING
Code No. /
functions
Operational procedure / display contents
14
Total
apparent
engine
speed
Monitor mode
Displays 1/10 of total apparent engine speed.
When total apparent engine speed is 10,350 rpm (min
-1
)
Command mode
Switches between forced setting and automatic setting (cancelling forced setting) of total apparent
engine speed.
Method of total apparent engine speed setting
Select command (Initial display)
During automatic operation During forced setting (9,000 → 10,450 rpm (min
-1
))
↓
Press [SET] switch
↓
Press [SET] switch
During command setting
Automatic setting Forced setting
→
←
Switch by pressing [UP] + [DOWN] switches simultaneously for 1 second
↓
Change data with [UP] or
[DOWN] switch
(changes by 50 rpm (min
-1
))
↓
Press [SET] switch
↓
Press [SET] switch
Return to select command (setting is completed)
Total apparent engine speed setting Completed
Automatic setting is completed. Forced setting is completed.
※ Displays 1/10 of total apparent engine speed.
※ Forced setting is automatically cancelled in 10 minutes.
※ This function is not available when the engine is not running.
※ Only one of the engine speeds (indicated, apparent, total apparent) may be forced at one
time.