276
TROUBLESHOOTING
Code No. /
functions
Operational procedure / display contents
68
Number of
starter
on/off times
69
Number of
engine
on/off times
6A
Nubmer of
compres-
sor 1
on/off times
6b
Nubmer of
compres-
sor 2
on/off times
Monitor mode
Displays the number of starter on/off times (code No. 68) / the number of engine on/off times (code
No. 69) / the number of compressor 1 on/off times (code No. 6A) / the number of compressor 2 on/
off times (code No. 6b) in times.
When the number of starter on/off times is 254,019 times
Alternately displayed
→
←
Check mode
Programs forced setting of the number of starter on/off times (code No. 68) / the number of engine
on/off times (code No. 69) / the number of compressor 1 on/off times (code No. 6A) / the number of
compressor 2 on/off times (code No. 6b) by 100 times. (available up to 300,000 times)
Example) Method of number of compressor 1 on/off times setting
Select command
In the case of change 123,456 → 50,000 times
Less than 100 times are dropped
↓
Press [SET] switch
During command setting
Digit of 100,000 times is flashing
↓
Change the flashing digit data with [UP] or [DOWN] switch.
↓
Press [SET] switch (Flashing digit moves to the right)
Digit of 10,000 times is flashing
↓
Change the flashing digit data with [UP] or [DOWN] switch. (with digit up/down)
↓
Press [SET] switch (Flashing digit moves to the right)
Digit of 1,000 times is flashing
↓
Change the flashing digit data with [UP] or [DOWN] switch. (with digit up/down)