277
TROUBLESHOOTING
(Continued)
68
Number of
starter
on/off times
69
Number of
engine
on/off times
6A
Nubmer of
compres-
sor 1
on/off times
6b
Nubmer of
compres-
sor 2
on/off times
↓
Press [SET] switch (Flashing digit moves to the right)
Digit of 100 times is flashing
↓
Change the flashing digit data with [UP] or [DOWN] switch. (with digit up/down)
↓
Press [SET] switch (all digits start flashing)
↓
Press [SET] switch
Return to select command (setting is completed)
Nubmer of compressor 1 on/off times setting Completed
Forced setting is completed.
70
Serial code
Monitor mode
Alternately displays the first 4 digits and last 4 digits of the serial code.
When serial code is A105CF82
Alternately displayed
→
←
71
Model code
Monitor mode
Model code is displayed on LED 2 and 1.
When model code is E1
Code No. /
functions
Operational procedure / display contents