Requirements
Fault: Off
PDH analyzer: No errors
Alarms reported on the ITM-CIT: “STM1cNES” (STM-1 Not Expected Input
Signal) on TP2.1 and TP2.2
...................................................................................................................................................................................................
9
Disconnect the incoming signal from the port in use.
Cleaning up
The following must be performed to clean up the system:
Reset the Alarm Reporting/Severity of the STM1cNES (STM-1 Not Expected Input
Signal) alarm to default (Not Reported).
Delete all cross-connections.
Stand-alone test procedures
Optical STM-1 option card test
...................................................................................................................................................................................................................................
7-18
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
E ND OF STEPS
...................................................................................................................................................................................................