X12SHDSL-V2 option card test
...................................................................................................................................................................................................................................
Overview
This test verifies that the X12SHDSL-V2 option card is properly installed and that it
functions correctly. In case of a DDF, the correct DDF labeling is checked by means of
port alarming.
Estimated duration
12 minutes.
Remarks
For this test an SHDSL E1 Modem (TU12/E1) is required. Do not connect it until
asked in the procedure.
SHDSL is the same as SDSL. SHDSL refers to the ITU-T standard and SDSL refers to
the ETSI standard.
Test setup
The following figure illustrates a possible test setup.
Note: For a long haul laser (L12 or L42), a 10 dB attenuator with applicable connector
is required in the loop.
Start condition
Be sure the following start condition is fulfilled:
The procedure in section “Preparation and test of the main unit” (p. 7-6) must have
been performed and the test results are correct.
X12SHDSL-V2 option card must be installed.
The ITM-CIT must be connected and logged-in to the NE.
Figure 7-6 X12SHDSL-V2 option card test
LP1.1
E1 modem
AM/AMS LTU with
X12SHDSL option card
E1 trib
SHDSL
E1 trib
TP1.*
SHDSL
TP2.*
Stand-alone test procedures
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
7-25