10 — 9500 MPR VLAN service management
10-12 September 2013 Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
Procedure 10-4 To create a CoS rate limiter per VLAN on a 9500 MPR
A CoS rate limiter per VLAN can be applied to each user Ethernet interface for the
ingress direction. The rate limiter is applied to a tagged Ethernet flow. The
combination of the values of one VLAN ID and one PCP identifies a specific VLAN
Ethernet flow.
1 Choose Equipment from the navigation tree view selector. The navigation tree
displays the Equipment view.
2 Expand the 9500 MPR NEs icon, then expand the Shelf icon.
3 Right-click on the port and choose Properties from the contextual menu. The
Physical Port (Edit) form opens with the General tab displayed.
4 Click on the CoS Rate Limiter tab and click on the Create button. The CoS Rate
Limiter (Create) form opens.
5 Click on the Select button and choose a Port Binding VLAN ID from the list. Click
on the OK button.
6 Configure the parameters:
PCP
Ingress CIR (kbps)
Ingress Max Burst (Kbytes)
7 Click on the OK button. A dialog box appears.
8 Click on the OK button. The CoS Rate Limiter (Create) form closes.