110 Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Chapter 4 Bulletin 290E/291E/294E Programmable Parameters
TripLog5
This parameter provides the fifth last trip
to occur.
Parameter Number 22
Access Rule GET
Data Type UINT
Group Trip Status
Units —
Minimum Value 0
Maximum Value 75
Default Value 0
SnapShotL1Amps
This parameter provides a snapshot of
actual Phase L1 current at time of last trip.
Parameter Number 23
Access Rule GET
Data Type INT
Group Trip Status
Units x.xx Amps
Minimum Value 0
Maximum Value 32767
Default Value
SnapShotL2Amps
This parameter provides a snapshot of
actual Phase L2 current at time of last trip.
Parameter Number 24
Access Rule GET
Data Type INT
Group Trip Status
Units x.xx Amps
Minimum Value 0
Maximum Value 32767
Default Value 0
SnapShotL3Amps
This parameter provides a snapshot of
actual Phase L3 current at time of last trip.
Parameter Number 25
Access Rule GET
Data Type INT
Group Trip Status
Units x.xx Amps
Minimum Value 0
Maximum Value 32767
Default Value 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley ArmorStart 294E and is the answer not in the manual?

Allen-Bradley ArmorStart 294E Specifications

General IconGeneral
BrandAllen-Bradley
ModelArmorStart 294E
CategoryController
LanguageEnglish

Related product manuals