250 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Appendix D Configure the Load Observer Feature
Setting Gains with Sercos IDN
Write Messages
Write the Load Observer Configuration attribute and the Load Observer gains
each time the drive gets initialized after applying power.
The Sercos IDN write instruction is accomplished by using RSLogix 5000®
software or the Logix Designer application. Refer to Appendix E on page 253
for more information on changing IDN parameter values by using this method.
1. Upon initialization of the drive, read the INT value of the configuration
of the drive at Sercos IDN P:0:431.
2. If the value is not what you want, latch it and write the new value back to
the drive at the same address, again as type INT.

Table of Contents

Other manuals for Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
Control TypeDigital
FeedbackResolver, Encoder
Protection RatingIP20
Power Range0.4…22 kW
CommunicationEthernet/IP
Ambient Temperature0°C to 50°C
AxisSingle-axis, Multi-axis
SafetySafe Torque-Off
Control ModesVelocity, Torque, Position
Relative Humidity5% to 95% (non-condensing)
Vibration Resistance5.9 m/s² (0.6 g) from 10 Hz to 500 Hz
Shock Resistance15 g, 11 ms
Storage Temperature-40°C to 70°C

Related product manuals