266 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Appendix F Enhanced Peak Performance
Change the Drive Parameter
Before the drive is capable of accepting a command for the new peak current
ratings, you need to change a drive parameter. This needs to be done only once,
and there are two methods to perform the task.
Sercos IDN Write Instruction
The Sercos IDN write instruction is accomplished by using the Logix Designer
application. Refer to Appendix
E on page 253 for more information on changing
IDN parameter values by using this method.
1. On initialization of the drive, read the INT value of the configuration of
the drive at Sercos IDN P:0:7.
2. If the value of bit zero is zero, latch it and write the new value back to the
drive at the same address, again as type INT.
IMPORTANT
The Sercos IDN method that uses the Logix Designer application supports
automatic drive replacement (ADR).

Table of Contents

Other manuals for Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
Control TypeDigital
FeedbackResolver, Encoder
Protection RatingIP20
Power Range0.4…22 kW
CommunicationEthernet/IP
Ambient Temperature0°C to 50°C
AxisSingle-axis, Multi-axis
SafetySafe Torque-Off
Control ModesVelocity, Torque, Position
Relative Humidity5% to 95% (non-condensing)
Vibration Resistance5.9 m/s² (0.6 g) from 10 Hz to 500 Hz
Shock Resistance15 g, 11 ms
Storage Temperature-40°C to 70°C

Related product manuals