EasyManuals Logo

Allen-Bradley Kinetix 6000 User Manual

Allen-Bradley Kinetix 6000
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017 269
Appendix G
RBM Module Interconnect Diagrams
This appendix provides Bulletin 2090 Resistive Brake Module (RBM)
interconnect diagrams specific to Kinetix® 6000 multi-axis servo-drive systems
with and without the safe torque-off feature.
Kinetix 6000 drives with the safe torque-off feature have the -S designation at
the end of the catalog number. For example, the 2094-AM01-S AM module
includes safe torque-off and the 2094-AM01 AM module does not.
Before You Begin
These procedures assume you have installed your RBM module with the
Kinetix 6000 servo-drive system. For RBM module installation instructions,
refer to the Resistive Brake Module Installation Instructions, publication
2090-IN009
.
For Kinetix 6000 drive systems, you can set the delay time for your RBM
module in the Logix Designer application. Refer to Configure Axis Properties
on page 151
.
Topic Page
Before You Begin 269
RBM Module Wiring Examples 270
IMPORTANT Drive firmware revision 1.071 or later is required to use the RBM module
with Kinetix 6000 drives.
ATTENTION: Use the interconnection diagrams as a general
recommendation of how the control circuit can be implemented. Actual
applications can vary due to requirements based on the machine builders
risk assessment. The machine builder must perform a risk assessment and
determine a category level of safety that must be applied to the machine.

Table of Contents

Other manuals for Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
Control TypeDigital
FeedbackResolver, Encoder
Protection RatingIP20
Power Range0.4…22 kW
CommunicationEthernet/IP
Ambient Temperature0°C to 50°C
AxisSingle-axis, Multi-axis
SafetySafe Torque-Off
Control ModesVelocity, Torque, Position
Relative Humidity5% to 95% (non-condensing)
Vibration Resistance5.9 m/s² (0.6 g) from 10 Hz to 500 Hz
Shock Resistance15 g, 11 ms
Storage Temperature-40°C to 70°C