Rockwell Automation Publication 2094-UM001J-EN-P - March 2017 257
Changing the Default IDN Parameter Values Appendix E
Write the New IDN Parameter Value
Follow these steps to write the new IDN parameter value.
1. Configure a Message Configuration (MSG) instruction to write the
IDN parameter value required for your application.
In this example, the Message Configuration (MSG) instruction is set to
write the additional bus capacitance of your leader IAM power module.
a. From the Message Type pull-down menu, choose Sercos IDN Write.
b. From the Identification Number pull-down menus, choose P-0-99.
2. Click New Tag.
3. The New Tag dialog box opens.
4. Type the name of your Source tag.
In this example, the tag name is Write_Value.
5. Click OK.
In this example, the new tag creates a source value (that you entered)
that the MSG instruction uses to overwrite the existing P-0-099 IDN
value.

Table of Contents

Other manuals for Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
Control TypeDigital
FeedbackResolver, Encoder
Protection RatingIP20
Power Range0.4…22 kW
CommunicationEthernet/IP
Ambient Temperature0°C to 50°C
AxisSingle-axis, Multi-axis
SafetySafe Torque-Off
Control ModesVelocity, Torque, Position
Relative Humidity5% to 95% (non-condensing)
Vibration Resistance5.9 m/s² (0.6 g) from 10 Hz to 500 Hz
Shock Resistance15 g, 11 ms
Storage Temperature-40°C to 70°C