EasyManua.ls Logo

Allen-Bradley Logix5000

Allen-Bradley Logix5000
708 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
212 Rockwell Automation Publication 1756-RM003N-EN-P - October 2011
Chapter 4 Input/Output Instructions (MSG, GSV, SSV, IOT)
DateTime DINT[7] GSV
SSV
The date and time.
Value Meaning
DINT[0] Year
DINT[1] Month (1...12)
DINT[2] Day (1...31)
DINT[3] Hour (0...23)
DINT[4] Minute (0...59)
DINT[5] Seconds (0...59)
DINT[6] Microseconds (0...999,999)
DSTAdjustment INT GSV
SSV
The number of minutes to adjust for daylight saving time.
LocalDateTime DINT[7] GSV
SSV
Current adjusted local time.
Value Meaning
DINT[0] Year
DINT[1] Month (1...12)
DINT[2] Day (1...31)
DINT[3] Hour (0...23)
DINT[4] Minute (0...59)
DINT[5] Seconds (0...59)
DINT[6] Microseconds (0...999,999)
TimeZoneString INT GSV
SSV
Time zone for the time value.
Attribute Data Type Instruction Description

Table of Contents

Other manuals for Allen-Bradley Logix5000

Related product manuals