Option
Number
Option Dis-
play Description Default Value Value Range
9
FH
Hot Water Temperature 140°F [60°C] 35°F-194°F [2°C-90°C]
10
FHC
Warm Water Temperature 100°F [38°C] 35°F-194°F [2°C-90°C]
11
FC
Cold Water Temperature 35°F [2°C] 35°F-194°F [2°C-90°C]
12
Codn
Cooldown Enable/Tempera-
ture
oFF oFF or
13
PtEn
Production Test Cycle (Ena-
ble/Disable)
on on/oFF
14
rAEn
Manual Rapid Advance
(Enable/Disable)
on on/oFF
15
nCtd
No Cycle Time Display
oFF on/oFF
16
PCtd
Programmable Cycle Time
Display
oFF on/oFF
17
SdAd
Slow Drain Detection Adjust 0 0-255 seconds
18
rtC-
Real Time Clock — —
a.
rtC1
Set Real Time Clock Minutes — 00-59
b.
rtC2
Set Real Time Clock Hours — 00-23
c.
rtC3
Set Real Time Clock Day — 001 (Sunday)-007 (Saturday)
d.
rtC4
Set Real Time Clock Date — 1-31
e.
rtC5
Set Real Time Clock Month — 1-12
f.
rtC6
Set Real Time Clock Year — 00 (2000)-99
g.
rtC7
Daylight Saving Option
on on/oFF
19
dAEn
Manual Diagnostics (Ena-
ble/Disable)
on on/oFF
20
FLo
Low Water Level 3 1-10
21
FnEd
Medium Water Level 15 11-20
22
FHI
High Water Level 27 21-30
23
tCF
Temperature Controlled Fill
oFF on/oFF
24
ALd-
Auto-Water Leak Detection — —
a.
ALd1
Auto-Water Leak Detection
(On/Off and cycles)
oFF oFF/0-127 (Cycles)
b.
ALd2
Auto-Water Leak Detection
Hour
0 0-23
c.
ALd3
Auto-Water Leak Detection
Day of Week
127* 0-127*
Table 1 continues...
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
19 Part No. F8238101ENR11