Option
Number
Option Dis-
play Description Default Value Value Range
(6)
S3
Supply #3 (Design 2 and 3
models)
**
on/oFF
(7)
S4
Supply #4 (Design 2 and 3
models)
**
on/oFF
c.
SdUr
Supply Duration ** Press START (enter) keypad
to access options
(i)
SEC
Seconds ** 0-59
(ii)
nIn
Minutes ** 0-9
4.
AgSt
Agitate Step — —
a.
AgEn
Agitate Step Enable/Disable **
on/oFF
b.
AdUr
Agitate Duration (in minutes) ** 1-30 for agitate types 1 or 2
1-180 for agitate types 3 or 4
c.
HEAt
Heat in Agitate (if heater is
present)
**
oFF/1/2**
5.
drAn
Drain Step
on on/oFF
6.
SPIn
Spin Step — —
a.
SPEn
Extract Step Enable/Disable **
on/oFF
b.
SSEC
Extract Seconds ** 0-59
c.
SnIn
Extract Minutes **
Intermediate Extract:
Min. Step Time = 30 sec-
onds
Max. Step Time = 3:59 mi-
nutes
d.
SSPd
Extract Speed (VFD only) ** 1-5* (Design 1)
1-6* (Design 2 and 3)
c.
Cnin
Cycle Time 0* 0-255 minutes
5
SUPC
Supply/Compartment Dis-
penser Programming (De-
sign 1 Models only)
C (Compartment) C (Compartment)
S (Supply Dispenser)
6
bALr
Number of Balance Retries
(VFD only)
Design 1: 3
Design 2 and 3: 1
1-7
7
IrA
IR Access (Enable/Disable)
on on/oFF
8
t FC
Fahrenheit/Celsius
FAHr (Fahrenheit) FAHr (Fahrenheit)
CEL (Celsius)
Table 1 continues...
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
18 Part No. F8238101ENR11