CHM1410R_SVG
(continued)
“IrA” - Enable/disable the ability to read
the control by an external device:
“on” = Enabled
“oFF” = Disabled
“t FC” (Models with Heat) - Set
temperature shown in Fahrenheit or Celsius.
“FH” (Models with Heat) - Set
the temperature of the hot water:
35°F - 194°F / 2°C - 90°C.
“FHC” (Models with Heat) - Set the
temperature of the warm water:
35°F - 194°F / 2°C - 90°C.
“FC” (Models with Heat) - Set the
temperature of the cold water:
35°F - 194°F / 2°C - 90°C.
“Codn” (Models with Heat) - Enable/Disable
the cool down water temperature option:
“oFF” or 50°F - 160°F / 10°C - 71°C.
“PtEn” - Enable/disable access to the
production test cycle:
“on” = Enabled
“oFF” = Disabled
“rAEn” - Enable/disable the rapid advance
feature:
“on” = Enabled
“oFF” = Disabled
“nCtd” - Enable/disable whether the cycle
time will appear in display:
“on” = Enabled
“oFF” = Disabled
“bALr” (VFD only) - Program the number
of times control will retry balancing the
load before moving to extract step: 1-7.
Temperature:
“CEL” = Celsius
“FAHr” = Fahrenheit
“SUPC” (Design 1 models only) -
Choose either supply dispenser
or compartment dispenser.
Dispenser:
“S” = Supply Dispenser
“C” = Compartment Dispenser
“SdAd” - Enable/disable slow drain
detection. When enabled can
increase/decrease the time before a slow
drain error will occur:
0-255 seconds
“rtC1” - Programs minutes:
“0” - “59”
“rtC2” - Programs Hours:
“0” - “23”
“rtC3” - Programs Day of Week:
“1” - “7”
“rtC4” - Programs Date of Month:
“1” - “31”
“rtC6” - Programs Year:
“0” - “99”
“rtC-” - set the control’s internal clock.
“rtC7” - Programs Daylight Saving:
“on” = Enabled
“oFF” = Disabled
“rtC5” - Programs Month:
“1” - “12”
“dAEn” - Enable/disable the manual
diagnostics option:
“on” = Enabled
“oFF” = Disabled
“PCtd” - Enable/disable
Programmable Cycle Time Display
“on” = Enabled
“oFF” = Disabled
“FLo” - Program the low water level
during fill and tumble of all cycles:
“1” - “10”
“FnEd” - Program the medium water level
during fill and tumble of all cycles:
“11” - “20”.
“FHI” - Program the high water level during
fill and tumble of all cycles:
“21” - “30”
“tCF” (Models with Heat) - Enable/disable a
temperature controlled fill
“on” = Enabled
“oFF” = Disabled
“ALd-” - Set the time and frequency that the
control automatically checks the water level.
“ALd3” - Auto-Water Leak Detection
Day of Week:
“0” - “127”
“ALd2”” - Auto-Water Leak Detection
Hour:
“0” - “23”
“ALd1” - Auto-Water Leak Detection:
“on”, then “0” - “127”
“oFF”