Diagnostics
CHM1411R_SVG
“dIAg” - Diagnostic Tests.
1. Press START (enter) keypad.
“d001” - Front End Control
Software Version # Test
“S xx”
“d002” - Output Board Control
Software # Test
“o xx”
“d003” - Output Board Water Level
Sensor Trim Value
“txxx”
“d004” - Top Cover Opening Test
“A oP” or “A CL”
“d017” - VFD Drive Fault Input
Test
“dFoP” or “dFCL”
“d013” - Termperature Sensor
Display Test
“xxxF” or “xxxC”
“d015” - VFD Balance Input Test
“bAoP” or “bACL”
“d016” - 24 VAC Switch Input Test
“ACoP” or “ACCL”
“d009” - Door Switch Input Test
“drCL” or “drOP”
“d010” - Door Lock Input Test
“drUL” or “drLO”
“d011” - Show Fill Time Test
“Fxxx”
“d012” - Show Drain Time Test
“dxxx”
“d014” - Start Pulse Test
“Stxx”
“d018” - Frame Balance Switch
Input Test
“FSoP” or “FSCL”
“d021” - Water Leak Detection
Test
“Ld”
“d020” - Water Purge Test
“PUrg”
“d022” - Custom Drive
Software Version # Test
“drxx”
(Design 2 and 3 Models)
“d023” - Custom Drive
Parameter Table
Version # Test
“dPxx”
(Design 2 and 3 Models)
“d024” - Custom Drive
Type Value
“dt x”
(Design 2 and 3 Models)
“d019” - Drive DC Bus
Display Test (Design 2 and 3 Models)
“d019” - VFD Balance Weight Test
“bAL” (Design 1 Models)