Production Test Cycle - Quick Reference Chart
Display Test Cycle Step Comments
dt xx
Drive Type Value
xx is the drive type value. Design 2 and 3
models only.
HFIL
Hot Fill to Low Level All water outputs turned off when Low
Level reached.
CFIL
Cold Fill to Low Level All water outputs turned off when Low
Level reached.
bFIL
Warm Fill to Low Level All water outputs turned off when Low
Level reached.
bFIH
Warm Fill to High Level All water outputs turned off when High
Level reached.
S1 for supply or C2Co for compartment
Supply #1 or Compartment #2 Cold Fill External supply #1. Design 2 and 3 models
only.
S2 for supply or C2Ho for compartment
Supply #2 or Compartment #2 Hot Fill External supply #4. Design 2 and 3 models
only.
S3 for supply or C3Co for compartment
Supply #3 or Compartment #3 Cold Fill External supply #2. Design 2 and 3 models
only.
S4 for supply or C4Ho for compartment
Supply #4 or Compartment #4 Hot Fill External supply #3. Design 2 and 3 models
only.
xxxF degrees F or xxxC degrees C de-
pending on the Fahrenheit/Celsius pro-
gramming parameter
Heat water to 110°F [43°C] or display
temperature
xxx is degree temperature. This step skip-
ped if not heat model. Heater turned off
when temperature reached.
LoAg
Reduced Wash Speed Forward with No
Agitation Action
This step skipped on 2 speed models.
Ag
Wash Speed Forward with No Agitation
Action
rAg
Wash Speed Reverse with No Agitation
Action
drAI
Drain Distribution Speed
PUrg
Factory Valve Purge
SP 1
Extract Speed #1 “very low” This step skipped on 2 speed models.
SP 2
Extract Speed #2 “low” This step skipped on 2 speed models.
SP 3
Extract Speed #3 “medium” This step skipped on 2 speed models.
SP 4 (VFD models) or
SPIn (2 speed models)
Extract Speed #4 “high” (VFD models)
SP 5
Extract Speed #5 “very high” This step skipped on 2 speed and F-speed
models.
Table 16 continues...
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
61 Part No. F8238101ENR11