To exit the Custom Drive Type Value, press the #5 (<) keypad.
The control will return to the Diagnostic Testing Mode.
Production Test Cycle
NOTE: Machine should be empty of water before start-
ing Production Test Cycle.
To Enter Production Test Cycle
1. Be certain control is in Start Mode and top cover or coin vault
is open.
2. While pressing and holding the #3 () keypad with one hand,
press the #7 keypad with the other hand.
3. When the control enters the Production Test Cycle, it will first
display S xx with the xx showing the software version of
the front end control.
4. The control will advance through the sequence of test steps
whenever any key is pressed. Refer to Table 16 for all tests in
the Production Test Cycle.
To Exit Production Test Cycle
To exit a test step, power down the machine.
Production Test Cycle - Quick Reference Chart
Display Test Cycle Step Comments
S xx
FEC Control Software Version
xx is the software version number.
o xx
Output Board Software Version
xx is the software version number.
Ct 3
Control Type 3 is the control type.
oPL
Control Type OPL
USA
Control Type Domestic
drAn or PUnP
Drain Type Drain or pump
tEnP
Temp Sensor Step skipped if not equipped with temp
sensor.
HEAt
Heater Step skipped if not heater-equipped.
rot
Rotation Sensor Step skipped if not Rotation Sensor-equip-
ped.
L dC or L AC
Door Lock Type
L dC for 24 VDC lock or L AC if 240
VAC unlock solenoid.
droP or drCL
Door Status Door status open or closed.
drUL or drLo
Door Lock Status Door will lock.
8.8.8.8. + all LEDs
Display Test All display elements are lit.
PAxx where xx = 1-12
Keypad Test Step Advance after all keypads are pressed.
A xx
Top Cover Switch Test
xx is either CL for closed or oP for open.
Cxxx or Pxxx
Machine Type/Size
xxx is machine capacity.
drxx
Drive Software Version Number
xx is the drive software version number.
Design 2 and 3 models only.
dPxx
Drive Parameter Table Version Number
xx is the drive parameter table version
number. Design 2 and 3 models only.
Table 16  continues...