TABLE 14. ENVIRONMENTAL SPECIFICATIONS
Operating temperature 0° C to +50° C (32° F to 122° F)
Storage temperature -20° C to 70° C (-4° F to 158° F)
Operating humidity < 80% non-condensing
Storage humidity < 95% non-condensing
Operating altitude range Up to 2,000 m (6,651 ft)
T
ABLE 15. INPUT SUPPLY VOLTAGE
Model Input supply voltage
GS970M/10
100-240 VAC, 50 - 60 Hz, 0.40A maximum
GS970M/18
GS970M/28 100-240 VAC, 50 - 60 Hz, 0.60A maximum
GS970M/10PS
100-240 VAC, 50 - 60 Hz, 2.4A maximum
GS970M/18PS
GS970M/28PS 100-240 VAC, 50 - 60 Hz, 6.4A maximum
T
ABLE 16. POWER SPECIFICATIONS
Model Power budget
Maximum power
consum
ption
GS970M/10 n/a 16 W
GS970M/18 n/a 18 W
GS970M/28 n/a 26 W
GS970M/10PS 124 W 161 W
GS970M/18PS 247 W 296 W
GS970M/28PS 370 W 459 W
Appendix : Appendix A: Technical Specifications
86
Environmental specifications
Power specifications

Table of Contents

Other manuals for Allied Telesis CentreCOM GS970M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis CentreCOM GS970M Series and is the answer not in the manual?

Allied Telesis CentreCOM GS970M Series Specifications

General IconGeneral
BrandAllied Telesis
ModelCentreCOM GS970M Series
CategorySwitch
LanguageEnglish

Related product manuals