AM8a Instruction Manual (18-0037) RS232 Entries and Printouts
0037-S07.L_58 February 10, 2000
7-19
(PEO) RS232 command equivalent switch te PCM
Emulate setup
Loop Voltage †(ELV) = 48 * - -
Loop Length (ELL) = 1200 * * -
Loop DC hold (EDH) = 330 - * -
2.16 µF (EIC) = IN * * -
Dialing type (ELT) = dial pulse - * -
Dialing start signal (ESS) = wink * - -
Unbalance Time (EUB) = 500 - - -
Ringing Voltage (ERV) = 085 * - -
Ringing Frequency (ERF) = 20.0 * - -
Ring on time (ER1) = 2000 * - -
Ring off time (ER2) = 4000 * - -
Ring on time (ER3) = 0000 * - -
Ring off time (ER4) = 0000 * - -
Ring on time (ER5) = 0000 * - -
Ring off time (ER6) = 0000 * - -
Dial tone delay (EDT) = 0250 * - *
Delay Begin (ELB) = 0100 * - *
Delay End (ELE) = 0250 * - *
Wink Begin (EWB) = 100 * - *
Wink Duration (EWD) = 250 * - *
Dial Tone Level (low) (EDA) = - 13 * - *
Dial Tone Frequency (EDB) = 350 * - *
Dial Tone Level (high) (EDC) = - 13 * - *
Dial Tone Frequency (EDD) = 440 * - *
Dial Tone on time (ED1) = 9999 * - *
Dial Tone off time (ED2) = 0000 * - *
Dial tone on time (ED3) = 0000 * - *
Dial Tone off time (ED4) = 0000 * - *
Dial tone on time (ED5) = 0000 * - *
Dial Tone off time (ED6) = 0000 * - *
Flash Time (EFS) = 500 - * -
Pulse Dial Speed (EPS) = 10 - * *
Pulse Dial % Break (EPB) = 60 - * *
Pulse Dial IDT (EPI) = 600 - * *
SF LEVEL (ESL) = - 10 - - -
SF FREQ% (ESF) = 00.0 - - -
Tone Dial Level (low) (ET3) = - 07 - * *
Tone Dial Frequency Tol (ET4) = 00.0 - * *
Tone Dial Level (high) (ET1) = - 07 - * *
Tone Dial Frequency Tol (ET2) = 00.0 - * *
Tone Dial on time (EEN) = 50 - * *
Tone Dial off time (EEF) = 50 - * *
Hold Tone Level (EHL) = - 10 * * *
Hold Tone Frequency (EHF) = 1004 * * *
† RS232 Command codes in "()" for reference; not printed (see Figure 7-4).
* Loop start parameters shown for analog switch and te.
Default parameters shown for PCM switch and te
Figure 7-5. Manual Short Print (EMULATE Analog Switch, Te, PCM Examples
7.2.7 Manual Long Print: To obtain a Long Print, press [SHIFT] then [PRINT], then hold the
[PRINT] key for 2 seconds. This will result in a Long Print, which prints all of the
information available for EVENTS details, METER displays, or SETUP parameters.
Figure 7-6 shows a sample of a Long Print while in the METER Display.