AMERITECH AM8a - Figure 6-2. Loop;Ground Start and DID Analog Test;Meter Front Panel Connections

AMERITECH AM8a
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Meter Display (18-0037) AM8a Instruction Manual
February 10, 2000 0037-S06.L_
6-4
RED (Ring—r)
LOOP
TIMS
TRUNK INPUTS
CAUTION: 10 VOLTS MAX
E & M
PCM2
TX RX TX/2W RX
E/M
SB/SG
PCM1
TX/2W RX
!
T/R
Connection made to
TIMS TX/2W jack
by the TIMS key
([SHIFT] [#, ST])
Z
monitor
emulate
TIMS
AM8a Terminates line in
Emulate Mode. Bridges
line in Monitor mode.
To TIMS
(AM5XT Shown)
GREEN (Tip—t)
BLACK (Sleeve—g)
Vt–r
Vr–g
Vt–g
Tone,
V cm
10, <330>, 430 ohms
It(ma) dc
24
21
1615
14
13
CO Ground
Noise
are pin numbers on
rear panel LINE/TIMS
connector.
n
TX/2W RX
RX TX/2W
bridging
terminated
Z
19 20
Figure 6-2. Loop/Ground Start and DID Analog Test/Meter Front Panel Connections

Table of Contents