AM8a Instruction Manual (18-0037) Emulation Parameters
0037-S03.L_24 February 10, 2000
3-5
DIAL TONE :
EMULATE 2 :
T1:dBm/hz
-13 350
T2:dBm/hz
-13 440
DL SNDms
250
15 to 9999 (1ms steps)
dBm = -40 to -3 (1dB steps)
Hz = 0 or 300 to 3300 (1 hz steps)
Alternate:
3.9.1 T1:dBm/hz: This parameter controls the level and frequency of the first tone of the
composite dial tone signal.
3.9.2 T2:dBm/hz: This parameter controls the level and frequency of the second tone of the
composite dial tone signal.
3.9.3 DL SNDms: This parameter is a delay time from seizure to providing the dial tone
when the AM8a is set to AUTOMATIC.
3.10 RECALL EMULATE
This menu is used for special calling features such as Call Transfer, Conference Calling, etc.
RECALL :
EMULATE:
HOOKFLASHms
500
15 to 999 (1ms steps)
LINE UNBALms
500
15 to 9999 (1ms steps)Alternate:
3.10.1 HOOKFLASHms: This is the duration of a Hook Flash generated by the AM8a.
3.10.2 LINE UNBALms: This is the International version of FLASH. The timing is utilized the
same way as flash. The difference is that an unbalance will apply a ground on the
ring lead for the programmed time.