EasyManua.ls Logo

AMERITECH AM8a - Dly Strt (Delay Start) Analyze; STRT Bgnms(Min;Max); Endms(Min); Wink Strt

AMERITECH AM8a
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AM8a Instruction Manual (18-0037) Analysis Parameters
0037-S04.L_32 February 10, 2000
4-3
4.4 DLY STRT (DELAY START) ANALYZE
When the EXPECTED TYPE of Start Signal is set to dialtone/delay, these parameters control
what is reported as an exception. If dialtone is received, these settings are not used.
DLY STRT:
ANALYZE:
STRT BGNms(min/max)
0 300
0 to 999 (1ms steps)
ENDms(min)
140
0 to 9999 (1ms steps)Alternate:
4.4.1 STRT BGNms(min/max): This is the time from off hook to the DELAY dial START
SIGNAL. If the timing is outside the range, it is flagged as an exception.
4.4.2 ENDms(min): This time must be exceeded in order for the delay signal to be valid. A
delay signal shorter than this time will be flagged as an exception.
4.5 WINK STRT
When the EXPECTED TYPE of Start Signal is set to dialtone/wink, these parameters control
what is reported as an exception. If dialtone is received, these settings are not used.
WINK STRT:
ANALYZE :
WINK BGNms(min)
15
15 to 999 (1ms steps)
DURms(min/max)
140 290
50 to 999 (1ms steps)
Alternate:
4.5.1 WINK BGNms(min): This is the time from off hook to the WINK START SIGNAL. If the
timing exceeds this parameter, it is flagged as an exception.
4.5.2 DURms(min/max): This is the time the wink signal must be present to be valid. A wink
signal less than the minimum (min) time or greater than the maximum (max) time of
this setting will be reported as an exception.