Configuration Parameters (18-0037) AM8a Instruction Manual
February 10, 2000 0037-S02.L_
2-10
CAUTION: When units are chained, set all parameters the same on each unit,
and do not exceed 2400 baud.
2.6.2 PARITY: This will select whether Even or Odd parity will be used for error checking.
This will also allow for NO parity check to be used.
2.6.3 CR DELAYsec: Carriage Return Delay. This parameter allows a delay to be inserted
after a carriage return is sent at the end of a line of text. This delay will prevent further
characters being sent during the time required for the carriage return in a printer
without a built-in buffer.
NOTE: The RS232 serial date will have the format of 1 stop bit and 7 data bits
when parity is enabled. When parity is disabled, 8 data bits will be used.
2.7 SECURITY CONFIG
The two security settings can only be changed by operator entry.
SECURITY:
CONFIG :
PASSWORD
no
yes
SETUP PROTECT
yes
noAlternate:
2.7.1 PASSWORD: is used for RS232 security. If PASSWORD is enabled ("yes"),
unauthorized access to the unit can be prevented. Access must be gained via a
"Logon" procedure. See the RS232 Entries and printouts in section 7 to set or change
passwords.
2.7.2 SETUP PROTECT: Setup allows the stored configuration to be protected from
accidental modification. When "yes" is selected and a STORE is attempted, the display
will indicate that Setup Protect is enabled; the STORE command will be ignored. To
STORE setups, set this parameter to "no".
NOTE: When Setup is PROTECTED, previously stored setups may be recalled as
normal. Also, parameters may be changed via the front panel controls or
RS232 commands.

Table of Contents