EasyManua.ls Logo

AMERITECH AM8a - Dialing Emulate; Loop Type; Start Signal; Pulse Emulate

AMERITECH AM8a
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Emulation Parameters (18-0037) AM8a Instruction Manual
February 10, 2000 0037-S03.L_
3-2
3.2.2 DC HOLD: This parameter controls the DC holding resistance placed across Tip and
Ring during an OFF-HOOK condition.
3.3 DIALING EMULATE
This menu controls the dialing type and the signal used as a start dial indication.
DIALING :
EMULATE:
LOOP TYPE
pulse
dtmf
mf(R1)
START SIGNAL
wink
Immediate
delay
dial tone
Alternate:
3.3.1 LOOP TYPE: This selects the dialing type the AM8a will out-pulse. This dialing type
may be changed using the "TOGGLE DIAL" key (or equivalent character in an AUTO
DIAL sequence).
3.3.2 START SIGNAL: This is the START SIGNAL provided by the AM8a when the START key
is pressed or the AM8a is in the AUTO mode and an OFF HOOK is detected.
3.4 PULSE EMULATE
The PULSE dialing specifications are programmed in this menu. These parameters are used
when the AM8a LOOP TYPE parameter is set to PULSE in the DIALING menu.
PULSE :
EMULATE:
SPEEDpps
10
5 to 25
BREAK%
60
40 to 85
INTRDIGITms
600
120 to 999
Alternate:
3.4.1 SPEEDpps: This controls the number of pulses per second for each digit out-pulsed.
3.4.2 BREAK%: This controls the % of break (open loop) of each pulse making up a out-
pulsed digit.
3.4.3 INTRDIGITms: The Inter-Digit Time is programmed here. This is the amount of time
from the last pulse of the previous digit until the first pulse of the next digit.

Table of Contents