(CS2) PCM: ON HK a/b. See CS1 list. 2.3.5 (2)
(CTT) TRUNK: TRUNK TYPE. (CTT = 00) for loop start, (CTT = 01) for ground start, (CTT
= 02) for E&M 2W, (CTT = 03) for <E&M 4W>, (CTT = 04) for did, (CTT = 05) for sf.
2.4.1
(CST) TRUNK: SLC® TYPE. (CST = 00) for <SINGLE PARTY>, (CST = 01) for
UNIVERSAL V G. 2.4.2
(CET) TRUNK: E&M TYPE. (CET = 00) for <I>, (CET = 01) for II, (CET = 02) for III, (CET =
03) for IV. 2.4.3
(CDM) DISPLAY: MODE. (CDM = 00) for manual, (CDM = 01) for <new call reset>, (CDM
= 02) for scroll. 2.5.1
(CDI) DISPLAY: DIG DET. (CDI = 00) for wide, (CDI = 01) for <narrow>, (CDI = 02) for
limit. 2.5.2
(CSM) DISPLAY: SLC® MSG. (CSM = 0000000000) to (CSM = 1111111111) for
0000000000 to <0000000001> to 1111111111. 2.5.3
(CMK) DISPLAY: “T/t” MASK. (CMK = 00) for <NO>, (CMK = 01) for YES. 2.5.5
(CBR) RS232: BAUD RATE. (CBR) = 300, 1200, 2400, or <9600>. 2.6.1 (@)
(CPT) RS232: PARITY. (CPT = 00) for <NO>, (CPT = 01) for ODD, (CPT = 02) for EVEN.
2.6.2 (@)
(CCD) RS232: CR DELAY sec. (CCD = 0) for <0> to (CCD = 99) for 99 sec. 2.6.3 (@)
(CPW) SECURITY: PASSWORD. (CPW = 00) for <no>, (CPW = 01) for yes. 2.7.1 (@)
(CSU) SECURITY: SETUP PROTECT. (CSU = 00) for no, (CSU = 01) for <yes>. 2.7.2
(@)
(CAE) PRINT: AUTO< PRINT. (CAE = 00) for <off>, (CAE = 01) for all calls, events onlyt,
(CAE = 02) for all calls, events & details, (CAE = 03) for flawed calls, events only,
(CAE = 04) for flawed calls, events & details. 2.8.1 thru 2.8.5
(CMM) CLOCK: DATE/MM. (CMM = 1) for 1 to (CMM = 12) for 12 (month). 2.9 (@)
(CDD) CLOCK: DATE/DD. (CDD = 1) for 1 to (CDD = 31) for 31 (day of month). 2.9 (@)
(CYY) CLOCK: DATE/YY. (CYY = 0) for 0 to (CYY = 99) for 99 (last 2-digits of year). 2.9
(@)
(CHH) CLOCK: TIME/HH. (CHH = 0) for 0 to (CHH = 23) for 23 (hour). 2.9 (@)
(CMT) CLOCK: TIME/HH. (CMT = 0) for 0 to (CMT = 59) for 59 (minutes). 2.9 (@)
No RS232
Command
AM8a: CPU DSP0 DSP1
105 100 100
Version is local display 2.10