Specifications
A-8 TM-F1OP-C1XN-01
Additional Features
Switching Frequency 6 V to 40 V models: nominal 78 kHz
(156 kHz output ripple);
60 V to 600 V models: nominal 62.5 kHz
(125 kHz output ripple).
Output Hold-up Time Greater than 20 ms (6 V model: 16 ms)
with interruption of AC line, for nominal
AC input and full load.
Maximum Voltage Differential
from either output to safety
ground
±600 Vdc
Insulation Resistance Input to chassis: >30 MΩ, with 500 Vdc;
a
Output to chassis: >20 MΩ, with 1000 Vdc.
a. To protect from power surges, the units have a 420 Vac varistor built in to act as an
over-voltage clamp. The above insulation resistance specification is subject to be measured
with the varistors taken out of the circuit
Isolation Voltage Input to output: 1350 Vac
TM-F1OP-C1XN-01.book Page 8 Thursday, October 25, 2007 9:04 PM