Rear Panel Connectors and Switch
TM-F1OP-C1XN-01 1-9
Rear Panel J2 Connector
The J2 Programming and Monitoring connector is a 15-terminal wire
clamp connector located on the power supply’s rear panel. See Figure 1-4.
The J2 connector provides access to the following functions:
Remote programming of output voltage AND/OR current limit
Remote monitoring of calibrated readback signals for output voltage
and output current
Remote control of the shutdown function using a 2.5 V to 15 V signal
See Table 1-3 for the list of the J2 connector terminal numbers, their
references, and corresponding functions.
Figure 1-4
Programming and Monitoring J2 Connector
1 Remote Output Voltage Programming Select
2 Remote Output Current Limit Programming Select
3 Control Ground
4 N/C
5 Voltage Program Signal Return
6 Output Voltage Programming Input
7 Current Program Signal Return
8 Output Current Limit Programming Input
9 Voltage Monitor Signal Return
10 Output Voltage Monitor
11 Current Monitor Signal Return
12 Output Current Monitor
13 N/C
14 Shutdown (S/D) Signal Return (–)
15 S/D Input (+)
TM-F1OP-C1XN-01.book Page 9 Thursday, October 25, 2007 9:04 PM