EasyManua.ls Logo

Ametek Sorensen XFR 1200 Watt Series - Inductive Loads; Figure 2-6 Output Voltage Connector with Shield

Ametek Sorensen XFR 1200 Watt Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Load Connection
TM-F1OP-C1XN-01 2-19
Inductive Loads
To prevent damage to the power supply from inductive kickback, connect
a diode across the output. The diode must be rated at greater than or equal
to the supply’s output voltage and have a current surge rating greater than
or equal to the supply’s output rating. Connect the cathode to the positive
output and the anode to the negative output/return.
Where positive load transients such as back EMF from a motor may
occur, connect a transorb or a varistor across the output to protect the
power supply. The breakdown voltage rating for the transorb or varistor
must be approximately 10% higher than the rated supply output.
Figure 2-6
Output Voltage Connector with Shield
(For 60 V to 600 V models)
Output Voltage Connector For 60 V to 600 V Models
+
DC OUTPUT
_
S/N: 4321
OPT:
Positive Output (+)
Negative
Output/Return (
)
Load Wires
Terminal
Screws
Shield
Knockout
Strain Relief
Strain Relief Screw
Stripped
Load Wires
0.35" (9 mm)
TM-F1OP-C1XN-01.book Page 19 Thursday, October 25, 2007 9:04 PM

Table of Contents

Related product manuals