Local and Remote Sensing
TM-F1OP-C1XN-01 2-23
Local and Remote Sensing
Use connections at the rear panel J10 sense connector to configure the
power supply for local or remote sensing of output voltage. See Figure 2-
11 for a drawing of the sense connector.
Sense Wiring
For lowest noise performance, use shielded pair wiring of 16 to 24 AWG
for remote sense lines. Strip wires 0.26 in. (6.5 mm), insert and tighten the
wire clamp.
WARNING
There is a potential shock hazard at the sense connector when using a
power supply with a rated output greater than 40 V. Select wiring with a
minimum insulation rating equivalent to the maximum output voltage of
the power supply for use as local sense jumpers or for remote sense wires.
For example, select TEW-105, 105 °C, 600 V wiring for use with a 600 V,
2 A model power supply. Ensure that connections at the load end are
shielded to prevent contact with hazardous voltages.