Installation
2-16 TM-F1OP-C1XN-01
6 V to 40 V Models
The 6 V to 40 V (low voltage) models have output bus bars and may come
with a bus bar shield in some configurations. To detach the shield before
connecting load wires, remove 6-32 x 1/4 in. screws (2), 6-32 x 3/8 in.
screw (1), and lock washers and flat washers (3 places). See Figure 2-4.
\
To make load connections to a 6 V to 40 V power supply:
1. Install a connecting wire terminal lug to load wiring (see Figure 2-5).
2. Fasten wire terminal lugs to bus bars with 1/4 in. x 1/2 in. (M6 x
12 mm) screws, 1/4 in. (M6) internal tooth lock washers, and hex nuts
as shown in Figure 2-5.
Figure 2-4
Bus Bar Shield
Shield
Flat Washer (3 places)
Lock Washer (3 places)
1/4" Screw (2 places)
3/8" Screw (1 place)
Important:
Bus bar hole sizes for the 6 V to 40 V models (low voltage) are:
1 of 0.332" (8.17 mm) D; and 2 of 0.197" (5.0 mm) D.