EasyManua.ls Logo

Ametek Sorensen XFR 1200 Watt Series - Environmental Specification; Figure A-3 Current Derating for Rack Mounted 6 V Models

Ametek Sorensen XFR 1200 Watt Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
A-10 TM-F1OP-C1XN-01
Environmental Specification
Operating Temperature Range 0 °C to 50 °C.
6 V model: for rack mounted units, derate
output current by 1.5 A per °C for operating
temperatures between 30 °C and 50 °C. See
Figure A-3.
Storage Temperature Range -20 °C to +70 °C
Humidity Range up to 90% RH non-condensing
Operating Altitude Up to 6,500 feet (2000 m)
Storage Altitude Up to 50,000 feet (15 000 m)
Installation Category II
Pollution Degree 2
Figure A-3
Current Derating for Rack Mounted 6 V Models
150
160
170
180
190
200
210
25 30 50
Output current (A)
25 30 50
AMBIENT TEMPERATURE (°C)
210
200
190
180
170
160
150
OUTPUT CURRENT (A)