Local Operation
3-10 TM-F1OP-C1XN-01
Table 3-2
Switch Settings for Shutdown Circuit Logic
Switch SW1-7 Setting Source Signal Signal Level Supply Output S/D LED
OFF (OPEN)
(Active low, default)
2-15 V HIGH OFF ON
0-0.4 V LOW ON OFF
ON (CLOSED)
(Active high)
2-15 V HIGH ON OFF
0-0.4 V LOW OFF ON
Important:
If switch SW1-7 is ON but there is no signal applied, the S/D LED
turns on and the power supply will not provide an output until the HIGH signal
level is applied.
Any of the eight switches on SW1 is OFF (OPEN) when it has been flipped up to
break contact, ON (CLOSED) when flipped down to close contact.