Remote Operation
4-6 TM-F1OP-C1XN-01
Table 4-2
Power Supply Settings for Different Programming Sources
Output
Voltage
Programming
Source
Output Current Limit Programming Source
0-5 Vdc 0-10 Vdc 0-5 k Resistor 0-10 k Resistor
None (Front
Panel Control)
0-5 Vdc
SW1: set 3 and 4
open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 3 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 2
closed, 3 and 4
open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 2
closed, 3 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 3 open.
J2: jumper 1 to 3.
0-10 Vdc
SW1: set 4 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: default
settings.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 2
closed, 4 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 2
closed.
J2: jumper 1 to 3
and 2 to 3.
SW1: default
settings.
J2: jumper 1 to 3.
0-5 k Resistor
SW1: set 1
closed, 3 and 4
open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1
closed, 3 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1 and 2
closed, 3 and 4
open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1 and 2
closed,
3 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 3 open,
1 closed.
J2: jumper 1 to 3.
0-10 k
Resistor
SW1: set 1
closed, 4 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1
closed.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1 and
2 closed, 4 open.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1 and 2
closed.
J2: jumper 1 to 3
and 2 to 3.
SW1: set 1
closed.
J2: jumper 1 to 3.
None (Front
Panel
Control)
SW1: set 4 open.
J2: jumper 2 to 3.
SW1: default
settings.
J2: jumper 2 to 3.
SW1: set 2
closed, 4 open.
J2: jumper 2 to 3.
SW1: set 2
closed.
J2: jumper 2 to 3.
SW1: default
settings.
J2: no jumper
TM-F1OP-C1XN-01.book Page 6 Thursday, October 25, 2007 9:04 PM