Table 1-3
Rear Panel J2 Connector Terminals and Functions
Connector Reference Name Function
J2-1 VRMT
Remote Output Voltage
Programming Select
Selects remote output voltage
programming when jumpered to pin 3.
J2-2 IRMT
Remote Output Current Limit
Programming Select
Selects remote output current limit
programming when jumpered to pin 3.
J2-3 CNTL GND Control ground. Control ground.
J2-4 N/C No connection None
J2-5 VPGM Voltage Program Signal Return Return for voltage program signal.
J2-6 VPGM
Output Voltage Programming
Input
Input for voltage programming signals
from an analog device.
J2-7 IPGM Current Program Signal Return Return for current program signal.
J2-8 IPGM
Output Current Limit
Programming Input
Input for current limit programming
signals from an analog device.
J2-9 VMON Voltage Monitor Signal Return Return for voltage monitor signal.
J2-10 VMON Output Voltage Monitor
Output for output voltage monitor
signal.
J2-11 IMON Current Monitor Signal Return Return for current monitor signal.
J2-12 IMON Output Current Monitor
Output for output current monitor
signal.
J2-13 N/C No connection None.
J2-14 S/D Shutdown Signal Return (–) Return for shutdown signal.
J2-15 S/D+ S/D Input (+) Input for shutdown signal.