Standard Operation
TM-F1OP-C1XN-01 3-5
Shipped Configuration
The factory ships units already configured for local control (front panel)
operation. See Table 3-1
for a summary of this configuration.
Table 3-1
Shipped Configuration (Local Control Mode)
Local Control Configuration Additional References
Use the front panel controls to adjust the output voltage
and current limit settings. (Note: Use the LOCAL
button only when you have a digital programming
interface installed.)
See “Local Operation” for front panel
operation. See “Remote Operation” for
remote analog programming procedure(s).
The supply’s sense point is at the rear panel J10 sense
connector terminals.
See page 2–23 for information on how to
change from local to remote sensing.
The OVP set point is adjusted at the front panel to
approximately 110% of rated output voltage.
See “Using Over Voltage Protection (OVP)”
on page 3–7 for the adjustment procedure.
The over temperature shutdown function automatically
resets when activated as determined by the position of
rear panel switch SW1-8. A latch off setting is also
available.
See “Over Temperature Protection (OTP)”
on page 3–16 for more information about
switch SW1-8 settings.