- 35 -
3378702_ATE_ut_GB ENGLISH
GB
#
A
CLEANING THE CONDENSATION COLLECTION CHANNEL AND TANK
To carry out this operation, proceed as follows.
) Clean and drain the condensation collection channel (A).
) Clean the condensation collection tank (B) and check that the drain hole and line are not
blocked.
CLEANING THE AIR FILTERS
To carry out this operation, proceed as follows.
) Switch o the appliance.
) Turn o the circuit-breaker to disconnect it from
the electrical mains.
) Open the lter door under the appliance and ex-
tract the air lter (C) and clean it.
C
VENT CLEANING
Users
To carry out this operation, proceed as follows.
) Run the steam oven at 100°C for half an hour.
) Switch o the oven and disconnect the power supply switch.
) Spray cleaning solution from the end of the vent hose (A) and let it sit for at least 15 minutes.
) Rinse the hose by spraying water into it from the end that opens onto the oven ceiling (do this
with the side of the oven closed).
) Manually rinse the inside of the cooking chamber or run an automatic rinse program.
Warning
A