116
17-3 Detailed RS232 command listing for the AR8600
Section 17-3
To set: BS
nnn...n
<CR>
Where
n
is a bank indicator in the range A-T or a-t
BS%%<CR> clears all link settings
BS%%
nnn...n
<CR> clears all link settings except
those listed
Examples:
BSABRabcmp<CR> toggles the link state for
the banks shown
BS%% BFT<CR> clears all links except for the
banks B, F & T
Note: As defined by GS.
CF Bandscope centre frequency
To read: CF<CR>
Responds with CF
nnnnnnnnnn
To set: CF
nnnnnnnnnn
<CR> or CF
nn.nnn
Set the bandscope centre frequency to the
specified frequency
(expressed in Hz or MHz depending on format)
Note: Maximum resolution is 10kHz for spans
10MHz - 500kHz; maximum resolution is 2kHz for
spans 200kHz-100kHz. Frequencies below 2kHz
are not accepted.
CN CTCSS Requires CT8200 option
To read: CN<CR>
Responds with CN
nn
nn
=0 (off),
nn
=01 (auto),
nn
=06-37 (a frequency from the following table)
nn
freq
nn
freq
nn
freq
nn
freq
00 off 10 136.5 20 241.8 30 177.3
01 auto 11 141.3 21 250.3 31 183.5
12 146.2 22 67.0 32 189.9
13 151.4 23 71.9 33 196.6
14 156.7 24 74.4 34 199.5
15 162.2 25 77.0 35 206.5
06 94.8 16 167.9 26 79.7 36 229.1
07 100.0 17 173.8 27 82.5 37 254.1
08 103.5 18 179.9 28 85.4
09 107.2 19 186.2 29 88.5
0A 110.9 1A 192.8 2A 91.5
0B 114.8 1B 203.5 2B 97.4
0C 118.8 1C 210.7 2C 69.4
0D 123.0 1D 218.1 2D 159.8
0E 127.3 1E 225.7 2E 165.5
0F 131.8 1F 233.6 2F 171.3
To set: CN
nn
<CR>, where
nn
is a two digit value from the table
DA Dial (VFO) audio squelch
To set: DA
nnn
<CR>
nnn
=000 - 255
(where 000=audio squelch off)
To read: DA<CR>
Responds with DA
nnn
or DA+
nnn
(+ = current audio squelch level >=
nnn
)
DB Dial (VFO) level squelch
To set: DB
nnn
<CR>
nnn
=000 - 255
(where 000=level squelch off)
To read: DB<CR>
Responds with DB
nnn
or DB+
nnn
(+ = current level >=
nnn
)
DC Data centre Frequency
To read: DC<CR>
Responds with DC
nnn
Example:
DC000
Note: Valid only when bandscope is on
Note: Refer to the LM command
DD Dial (VFO) delay
To set: DD
nn
<CR>
Where
nn
= 00 - 99 or FF
(indicating 0.0 - 99 seconds or FF=hold)
To read: DD<CR>
Responds with DD
n.n
^A Remote ID Hex value 0x01
Accepts a value
nn
in the range 01-99
AF AFC To set: AF
n
<CR>
n
=0 (off),
n
=1 (on)
To read: AF<CR>
Response is AF
n
Note: Not valid in WFM, USB, LSB or CW
AM Bandscope Analyser Mode
AM<CR> starts bandscope mode
AM<CR> repeated when in bandscope mode
generates a report in the following format:
AM PH0 CF0091000000 MF0091000000 SW1
AP Auto Pwr off AP
n.n
<CR>
n.n
=0.0 (off)
nn
=0.5-9.5 (sets 0.5 - 9.5 hours to power off
following last active transmission)
To read: AP<CR>
Responds with AP
n.n
(where
n.n
is the delay time
in hours or 0.0 = off)
Note: n.n must be in multiples of 0.5 hours
AS Search auto-store on/off
To set: AS
n
<CR>
n
=0 (off),
n
=1 (on - write frequency into bank J),
n
=2 (on - same as 1 but erase previous channels
to create space for new entries),
To read: AS<CR>
Response is either
n
=0 (off) or
n
=1 (on)
Note: Stores into the search group nominated
by GS
AT Attenuator To set: AT
n
<CR>
n
=0 (off),
n
=1 (on)
To read: AT<CR>
Response is AT
n
, where
n
=0 (off) or 1 (on)
AU Auto mode To set: AU
n
<CR>
n
=0 (off),
n
=1 (on)
To read: AU<CR>
Response is AU
n
MD
m
BM Scan bank link setting
To read: BM<CR>
Responds with: BM
nnnnnnnnnnnnnnnnnnnn
,
where
n
= character corresponding to linked bank
(A - J or a - j), or - (not linked)
Example: BM-BCD---------------- indicates that
banks B, C & D are linked
To set: BM
nnnnnnnnnnnnnnnnnnnn
<CR>
Where
n
is a character which specifies a bank
which will have its link status toggled (A - J or
a - j). There is no need to enter a “-” to avoid
changing a bank link
BM%%<CR> clears all link settings
BM%%
nnnnnnnnnnnnnnnnnnnn
<CR> clears all
links except those specified
Examples: BM abc toggles the link status for
banks a, b & c
BM%% bc clears the link status for all banks
except b & c
Note: As defined by GM.
BP Search Bank Protect
To set: BP
n
n
=0 (off),
n
=1 (on)
To read: BP<CR>
Response is BN
n
BS Bank link search
To read: BS<CR>
Responds with: BS
nnn...n
, where
n
= character
corresponding to linked bank,
or - (not linked). The search bank indicators range
from A - T and a - t (40 search banks in all)
Example:
BS-BC---F-HIJ-------R--a---e--h-j----no---st
Indicates that the banks shown are linked.