121
where
x
= A-T or a-t
Recalls search bank
x
SR%%<CR>
Responds with a listing of all search
banks A-J
Responds with:
SR
x
SL
nnnnnnnnnn
SU
nnnnnnnnnn
ST
nnnnnn
AU
n
MD
n
TT
xxx...x
or
SRR ---
for a blank bank
Note: Refer to the individual commands for
further details
SS Start search SS<CR>
Start searching using the current
search bank
SS
x
<CR>
Start searching using the parameters
stored in search bank
x
(A-T or a-t)
ST Tuning step size To set: ST
nnnnm0
<CR>
Set the tuning step size in Hz
To set: ST
nnn.nm
<CR>
Set the tuning step size in kHz
ST+
nnnnm0
, ST+
nnn.nm
or ST+
turns on step adjust
To read: ST<CR>
Responds with value, format:
ST
nnnnm0x
(
x
=+ step adjust on)
SU Upper search
frequency limit See RF command for format of
frequency
SW Bandscope
Span Width To set: SW
n
<CR>
Where
n
= 1 - 7 as follows:
1 10.0MHz
2 5.0MHz
3 2.0MHz
4 1.0MHz
5 500kHz
6 200kHz
7 100kHz
To read: SW<CR>
Responds with SW
n
(where
n
has a
value as above)
TB Set Text Description
for Bank To set: TB
nxxxxxxxx
<CR>
Sets the text for bank
n
(A-J or a-j) to
be the 8-character ASCII comment specified
TB<CR> or TB%%<CR>
Responds with a complete listing of
the comments for each bank in the
following form:
TB
MW A:50 TBAAOR Test
MW a:50 TBa
MW B:50 TBBAOR
MW b:50 TBb
MW C:10 TBCAOR Test
MW c:90 TBc
MW D:50 TBDAOR Test
MW d:50 TBd
MW E:50 TBE
MW e:50 TBe
TB
x
<CR>
Responds with the text for bank x in
the following format:
TBA
TBAAOR Test
TI Set priority
interval To set: TI
nn
<CR>
Sets priority interval
nn
(01-19) in seconds
To read: TI<CR>
Responds with TD
nn
(
nn
is current priority interval
value expressed in seconds)
TM Memory Text To write: TM
xxx...x
<CR>
Where
xxx...x
is a 12-character ASCII text
comment
Note: See TT command.
Section 17-3
TS Text Search TS
xxx...x
<CR>
Searches for the specified text in a
memory channel
Where
xxx...x
is a minimum of 2
characters and a maximum of 11
characters of ASCII text comment
Note: The more characters specified
the faster the search
Note: When the text search has
completed, <CR> is returned
Note: When the RX<CR> command
is issued with TS, the relative bank
and channel number will be shown
TT Search Bank Text To set: TT
xxx...x
<CR>
Where
xxx...x
is a 12-character
ASCII text comment
Note: See SE command
VA/VB Set VFO A - B
To set: V
xnnnnnnnnm0
<CR> (in Hz) or V
xnnnn.nnnnm
<CR> (in MHz)
Where:
x
is A or B for VFO A or B,
frequency data is expressed in the
format used by the RF command
V
x
<CR>
Selects VFO
x
(A or B), there is no
data returned from the radio
VF Select 1-VFO To set: VF<CR>
VL Beep volume level To set: VL
n
<CR>
Where,
n
= 0 - 9 (0=off)
To read: VL<CR>
Responds with VL
n
as above
VR Firmware Version To read: VR<CR>
Responds with data of the form:
VR
VR0101
VS VFO search VS<CR>
Starts a VFO based search with
limits defined by the frequencies in
VFO A & B
VT VFO auto-store To set: VT
n
<CR>
Where
n
is defined as follows:
0 Off
1 On, Auto-store to bank J
2 On, erase bank J
To read: VT<CR>
Responds with VT
n
as above
Note: VT2 response is equivalent to
VT1
VV VFO Scan To set: VV
n
<CR>
Where
n
=0 (2-VFO mode) or
n
=1
(VFO scan mode)
WM Write Protect Bank To set: WM
xn
<CR>
Where
x
is bank (A-J or a-j) and
n
=0
(protect off),
n
=1 (protect on)
To read:
WM<CR> or WM%%<CR>
Responds with a listing of 10 banks
starting from the last queried bank.
Example:
WM
WM F0
WM f0
WM G0
WM g0
WM H0
WM h0
WM I0
WM i0
WM J0
WM j0
WP Write protect
enable To set: WP
n
<CR>
Where
n
=0 (disabled)
or n=1 (enabled)
To read: WP<CR>
Responds with WP
n
as above

Table of Contents