Octave Configuration Guide 20
Pulses Alarms
Mode - set whether alarm information is included in the output.
“Off” – alarm information is not included
“On” – alarm information is included
Alarms Period (sec) - when alarm information is included in the output, set the
alarm signaling pattern that matches your diagnostic & billing device as follows:
Alarm Repeat Time (hr) – when alarm information is included in the output, set
the interval between logging the alarm in the output (if the reason for triggering
the alarm was not resolved within this interval).
Alarms – select the check boxes of those conditions that will trigger alarms (via
the meter’s output that reaches the control center):
Low Battery – meter’s battery power is low. Alarm will be triggered
when there is about a month of power left in the battery.
Measurement Fail – failure in collecting the data required for
calculating water flow.
Leakage – when a given start time passes with the flow above the
configured threshold (see Alarm Thresholds).
Flow Rate Alarm – when the flow rate exceeds the top threshold
(see Alarm Thresholds).
1 second issues 9 successive pulses
2 seconds issue 18 successive pulses
3 seconds issue 27 successive pulses
4 seconds issue 36 successive pulses
5 seconds issue 45 successive pulses

Other manuals for Arad Octave

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arad Octave and is the answer not in the manual?

Arad Octave Specifications

General IconGeneral
Protection ClassIP68
TypeUltrasonic flow meter
CommunicationM-Bus
Pressure Rating16 bar
Power SourceInternal battery

Related product manuals