Octave Configuration Guide 45
Alarms Logs
Per the selected event types (system and flow), specify which events will be
included in the logged data.
System
Measurement Fail – select this check box to log measurement failure data.
Low Battery – select this check box to log low battery alarm data.
Critical Change – select this check box to log critical change data.
Tamper Detection – N/A
Flow
Leakage – select this check box to log leakage alarm data.
Flow Rate Alarm – select this check box to log flow rate alarm data.
Reverse Flow – select this check box to log reverse flow alarm data.
Pipe Burst – select this check box to log pipe burst alarm data.
Dry Pipe - N/A
NOTE: Tap Save to keep your changes. Tap Revert to return the meter logs
settings to the last saved configuration.
If needed, tap Record to create a manual output file per the recording
configuration in Application Settings.