Octave Configuration Guide 35
Mbus
When using the M-Bus protocol to output data, specify the communication
settings that match your environment.
Mode – select whether the M-Bus output should include Pulse data
“Mbus” – only M-Bus supported data is included in the output string.
“Mbus + Pulse” – both M-Bus and Pulse data is included in the
output string.
Mbus
AMR Serial Number – the meter’s auto-detected serial number (Automatic
Meter Reading).
Units – set the output units. The available flow rate-volume unit combinations
are:
Flow Rate: m
3
/h - Volume: m
3
Flow Rate: GPM - Volume: GAL
Flow Rate: GPM - Volume: Ft
3
(cubic feet)
Refer to the Glossary for unfamiliar abbreviations.
Slave Address – set the slave address used for the Octave meter in the range
of 1 to 247.
Flow Resolution – set the resolution for the transferred flow-rate output.

Other manuals for Arad Octave