Sonata Pulse Configuration Guide ii
Chapter 6
Alarm Thresholds
Overview . . . . . . . . . . . . . . . . . 40
Configuration . . . . . . . . . . . . . . . 40
Flow Rate Alarm . . . . . . . . . . . . . . 41
Leakage . . . . . . . . . . . . . . . . . . 41
Pipe Burst . . . . . . . . . . . . . . . . . 42
Reverse Flow . . . . . . . . . . . . . . . 42
Chapter 7
Meter Logs
Overview . . . . . . . . . . . . . . . . . 43
Meter Logs . . . . . . . . . . . . . . . . 43
Configuration . . . . . . . . . . . . . . . 44
Alarms Logs . . . . . . . . . . . . . . . . 45
System . . . . . . . . . . . . . . . . . 45
Flow . . . . . . . . . . . . . . . . . . 45
Chapter 8
Advanced
Overview . . . . . . . . . . . . . . . . . 46
Clock Settings . . . . . . . . . . . . . . . 47
RTC Date Time . . . . . . . . . . . . . 47
Shabbat . . . . . . . . . . . . . . . . 48
LCD Test . . . . . . . . . . . . . . . . . 49
Totalizer Data . . . . . . . . . . . . . . . 50
Volume Totalizer . . . . . . . . . . . . 50
Special Functions . . . . . . . . . . . . . 51
Flow Simulation . . . . . . . . . . . . . . 52
Simulating flow . . . . . . . . . . . . . 52
Application Settings . . . . . . . . . . . . 53
Graph . . . . . . . . . . . . . . . . . 53
Recording . . . . . . . . . . . . . . . 53
Configuration Files . . . . . . . . . . . 55
About . . . . . . . . . . . . . . . . . . . 56
Exit . . . . . . . . . . . . . . . . . . . . 57
Chapter 9
Troubleshooting
Error messages . . . . . . . . . . . . . . 58
Possible issues . . . . . . . . . . . . . . 60
Meter values not updated . . . . . . . . 60
Display and output mismatch . . . . . . 60
Unintended disconnect . . . . . . . . . 60
Chapter 10
RS-232 Connection
Overview . . . . . . . . . . . . . . . . . 61
Removing the tamper-protective shield . . . 62
Connecting the communication module to
the water meter . . . . . . . . . . . . . . 64
Connecting the communication module to
the PC (Windows 7/10) . . . . . . . . . . 65
Arad Smart Meters serial connection
settings . . . . . . . . . . . . . . . . . . 66
Attaching the tamper-free shield . . . . . . 67
Chapter 11
Glossary
Units used in Arad Smart Meters . . . . . . 68

Other manuals for Arad Octave

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arad Octave and is the answer not in the manual?

Arad Octave Specifications

General IconGeneral
Protection ClassIP68
TypeUltrasonic flow meter
CommunicationM-Bus
Pressure Rating16 bar
Power SourceInternal battery