Table 18. The Askey 5G NR Small Cell Neighbor Cell Configuration
Items
Descriptions
NeighborCell AbsArfcnSsb
The absolute ARFCN point A configuration of the neighbor cell
A3 RSRP Offset
The Reference Signal Received Power (RSRP) offset of event A3.
The number range is -30 to 30 (dB).
A3 Hysteresis
The hysteresis value of event A3.
The number range is 0 to 30 (dB).
A3 Timer To Trigger
The timer helps to avoid irregular measurement and handover. Support the following items:
MS0, MS40, MS64, MS80, MS100, MS128, MS160, MS256, MS320, MS480, MS512, MS640,
MS1024, MS1280, MS2560, MS5120
XN Enable
If checked, the device will enable the Xn handover. It needs to choose the server or client side for
Xn handover
XN Neighbor IP
The IP address of the peer gNB on the Xn interface
3.5.4 RF Antenna
This Askey 5G NR Small Cell RF Antenna page allows users to modify the max TX power and the RF
antenna path.
Figure 44. The Askey 5G NR Small Cell RF Antenna Page