EasyManua.ls Logo

Atlas Copco FlexiROC T30 R - Preparing Water Mist System for Long Time Storage; Restoring after Long Period of Downtime; Inspection and Maintenance During Period of Downtime

Atlas Copco FlexiROC T30 R
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FlexiROC T30 R 21 Downtime
138 No: 3629357835.1.3629419915 en-US
2.
Apply corrosion inhibitor (For example, Tectyl 506) to the machined surfaces.
3.
Apply touch-up paint to any scratches and damage on painted areas.
21.1.4 Preparing Water Mist System for Long Time Storage
1.
Drain the water mist system.
2.
Rinse with anti-freeze.
3.
Blow dry the water mist system with compressed air.
21.2 Restoring After Long Period of Downtime
n Change lubricant and hydraulic oil where appropriate.
n Change filter and drain water separators where appropriate.
n Inspect joints, bushings and splines for corrosion. Remedy any corrosion by cleaning
or replacing components.
n In order to remove any moisture binding from lubrication points: Pump new grease into
the grease nipples and apply grease with a brush to sliding surfaces and splines where
these occur. Use the correct grease for each point.
n Carry out special startup as instructed.
21.3 Inspection and Maintenance During Period of
Downtime
n Check levels for oils and coolants.
n Start the diesel engine and run until the normal operating temperature is reached.
n Operate the machine a few metres back and forth so that the tramming gears are lubri-
cated.
n Operate the tilt cylinders, boom, feeder, drill rod support, and rod handling until all
cylinders reach their end positions.
n Drain condensed water from the hydraulic oil tank and compressor oil tank.
n Rotate the electric motors a few turns at least every three months to avoid spot dam-
age on motor bearings.