FlexiROC T30 R 8 Drilling System
56 No: 3629357835.1.3629419915 en-US
8.6.2 Setting Lubricant Oil Dosage
The setting for the dosage of lubricant oil for the rock drill (ECL) and the screw cutting oil
(ECG) is made in the operator panel.
Precondition
p
Dust Collector and Flushing Air switch in On position.
p
Lubricant dosage must be set with the engine switched off and the ignition key in drive
state.
1.
Go in under Settings and confirm with Enter .
2.
Select ECL or ECG using the arrow and , confirm with Enter .
3.
Set the values as desired. There are two values that can be adjusted:
a.
Pulses/minute:The number of pulses per minute.
!
NOTE: Factory setting is 30 pulses/minute.
b.
Extended time:Total time that lubrication is active after flushing air is switched
off.

Table of Contents